Key Parameters of the Cooling Fan Explanation
1) Size specification:
The selection of Fans must strictly comply with the structural space constraints of the entire machine. Their external dimensions are usually represented by a four-digit code (such as 4010, 4020, 5010, 9025), where the first two digits indicate the length of the square installation surface (unit: mm), and the last two digits indicate the axial thickness (unit: mm).

2) Power consumption:
The electrical power drawn by the fan during operation, calculated as the product of its rated operating voltage and maximum current draw. Units are expressed in watts (W). Lower power consumption reduces motor thermal loading, thereby enhancing long-term operational reliability and service life.
3) Operating voltage:
Common nominal DC supply voltages for Cooling Fans include 5 V, 12 V, 24 V, and 48 V. The minimum voltage required to initiate rotation from standstill—termed the start-up voltage—is a critical performance parameter reflecting motor winding design, bearing friction, and overall drive efficiency. Fan selection must align with the system’s available regulated DC rail voltage to ensure reliable operation.
4) Rated current:
The current value marked on the fan’s nameplate, representing the maximum steady-state current drawn under specified rated operating conditions—including full-load speed, nominal voltage, and standard ambient temperature—as determined by the manufacturer through design validation and type testing. In practice, this value is rarely reached during normal operation; transient current surges occur only briefly at startup, while steady-state current typically remains significantly lower due to dynamic load reduction and thermal stabilization.
5) Rotational speed (RPM):
The number of complete revolutions the fan impeller makes per minute. This parameter is determined by multiple interdependent factors, including motor winding configuration (e.g., coil turns), applied voltage, and aerodynamic design parameters—such as blade count, pitch angle, hub-to-tip ratio, overall diameter, and bearing type. While higher rotational speed generally enables greater airflow and static pressure generation, it also correlates strongly with increased aerodynamic and mechanical noise emissions.
6) Pressure–flow characteristic curve (P–Q curve):
A graphical representation of the relationship between static pressure differential and volumetric airflow rate for a fan operating at a constant rotational speed. The stall point (zero airflow) defines the maximum static pressure, while the free-air point (zero system resistance) defines the maximum airflow—both determined under controlled wind tunnel test conditions per AMCA 210 or ISO 5801 standards. In real-world thermal management applications, the actual operating point lies along the curve’s mid-section, constrained by the system’s aerodynamic impedance. For a given fan at fixed speed, airflow and static pressure exhibit an inverse relationship.

7) Acoustic noise:
The sound pressure level generated during fan operation, expressed in decibels (dB(A))—weighted according to the A-frequency response curve to reflect human hearing sensitivity. Primary noise sources include aerodynamic noise (e.g., blade passage tones and tip vortex shedding) and mechanical noise (e.g., bearing friction, rotor imbalance-induced vibration). For office-environment equipment, acoustic emission is typically constrained to ≤40 dB(A) to comply with occupational and ambient noise guidelines (e.g., ISO 11690-1, GB/T 2888.2).
8) Service life:
As the sole rotating component in most thermal management systems, cooling fans represent a primary reliability bottleneck. System-level thermal design reliability is therefore heavily dependent on fan service life. Key influencing factors include bearing type and lubrication, driver IC quality, manufacturing process control, operational rotational speed, ambient temperature, humidity, and particulate exposure. Among these, bearing technology (e.g., sleeve vs. ball vs. fluid dynamic), driver IC thermal robustness, and operating temperature—particularly junction temperature of motor windings—are the dominant determinants of longevity. To validate suitability, engineers must explicitly define the intended application environment (including temperature profile, duty cycle, and contamination class), establish the required system design life, and formally verify—via supplier datasheets, accelerated life test reports (e.g., MIL-HDBK-217 or Telcordia SR-332), and contractual agreements—that the selected fan’s rated service life meets or exceeds the target.