When choosing a cooling fan, should we consider the static pressure or the dynamic pressure?
I. Core Differences Between Static Pressure and Dynamic Pressure (Perspective of Both Popular and Professional)
The fundamental difference between the two lies in the form of energy and the applicable conditions. According to Bernoulli's equation: Total Pressure = Static Pressure + Dynamic Pressure. When the total pressure remains constant, the two can be converted into each other - for example, as the flow velocity increases, the dynamic pressure rises, and the static pressure decreases accordingly. The table below and the concise explanation can help you quickly grasp the key differences.

In simple terms: Static pressure determines "penetration power", while dynamic pressure determines "wind speed". If the static pressure is insufficient, even if the wind is very fast, it still cannot penetrate the dense fin plates; if the dynamic pressure is insufficient, even if the penetration occurs, the low wind speed will prevent effective heat dissipation.
II. Selecting Cooling Fans: Should We Focus on Static Pressure or Dynamic Pressure? (Core Selection Logic)
Conclusion first: The core of the selection is not a "binary choice" but rather "consider the scenario and match the resistance" - the actual cooling effect of the cooling fan depends on whether the static pressure can overcome the system resistance, and whether the dynamic pressure can ensure sufficient wind speed. Both are indispensable, but priority should be given to matching the scene resistance (that is, prioritize checking whether the static pressure is compatible).
The resistance level in the cooling scenario is the core basis for determining whether to focus on static pressure or dynamic pressure. According to the resistance characteristics, it can be classified into three categories:
1. High resistance scenario (priority to static pressure, with consideration for wind speed)
When there are obvious obstacles in the air path (such as dense fins, filters, long ducts), when the static pressure is insufficient, the airflow will be blocked outside - even if the wind speed is high, the actual air volume passing through the cooling components is severely reduced.
Typical applications: CPU/GPU air-cooled coolers, water-cooled radiators, cases with dust filters, servers, industrial controllers, long duct equipment.
Selection suggestion: Choose high static pressure fans (recommended static pressure ≥ 2.0 mmH₂O), and ensure that the wind speed is sufficient to maintain effective heat exchange (avoiding too low flow rate after penetration); Opt for narrow blade tip gap and strong support blade design to enhance resistance resistance.
Note: If only pursuing high wind speed, it is prone to the phenomenon of "fan running at high speed, feeling strong wind, but the core temperature does not drop" - the airflow is largely blocked by fins or filters, and the heat cannot be dissipated.
2. Low-resistance scenario (priority on dynamic pressure, with consideration for static pressure)
The air path is unobstructed, and there are no significant barriers. The system resistance is extremely low. At this time, the static pressure requirement is low, and the dynamic pressure directly determines the wind speed and volume - the higher the wind speed, the higher the heat dissipation efficiency.
Typical applications: Open desktop cooling, filterless chassis (bare chassis), room ventilation, open air ducts for large equipment.
Selection suggestion: Preferentially select high dynamic pressure and large volume fans (recommended wind volume ≥ 70 CFM); the static pressure only needs to meet the basic circulation requirements; a large-blade DC fan can be selected to ensure the wind volume while also considering noise reduction.
3. Balanced Scene (Static Pressure and Dynamic Pressure Must Work Together)
There is a slight system resistance, which requires both a certain penetration force and stable wind speed. Both must be coordinated and matched, and neither should be neglected.
Typical Applications: Ordinary cases (including simple filters, without dense fins), routers, set-top boxes, and small household appliances for heat dissipation.
Selection Suggestions: Choose fans with balanced static pressure and dynamic pressure; mainly refer to the "static pressure – air volume curve" provided by the manufacturer to ensure that at the commonly used speed, the static pressure is sufficient to overcome the resistance, and the air volume can maintain effective heat exchange; prefer models that support PWM speed control, taking into account both heat dissipation performance and operating noise.
III. Selecting the Right Model: Two Key Reminders
1. Do not blindly pursue "high air volume"
Some fans have a high rated airflow, but the static pressure is extremely low. In high-resistance scenarios, the actual effective airflow will significantly decrease (for example, a rated 80 CFM may only remain at 40 CFM after passing through dense fins). The heat dissipation effect will drop significantly.
2. Reserve Safety Margin
It is recommended to reserve a 10%–30% margin for the static pressure parameter: If the calculation requirement is 2.0 mmH₂O, a model around 2.5 mmH₂O can be selected. This measure can cope with the increase in resistance caused by dust accumulation in the filter, aging of the air duct, etc., and ensure long-term heat dissipation stability.
Selection Tips:
High resistance (dense fins/filters/enclosed or long air duct) → Prioritize static pressure;
Low resistance (unobstructed, open ventilation) → Prioritize dynamic pressure;
Normal scenarios → Select based on the manufacturer's "static pressure–airflow curve" in combination with static pressure and dynamic pressure to ensure long-term heat dissipation stability.